High Energy Savings That Delivers High COP

Daikin's SUPER MULTI NX offers outstanding performance and the high COP through such key technological advances as our reluctance DC motor. This motor greatly improves the efficiency of rated capacity operation, and increases the efficiency of small load operation as well by 42%.

High COP

High COP

* During rated capacity operation of 4 indoor units (2.5 + 2.5 + 2.5 + 6.0 kW class).


What is COP?

COP = Capacity(kw) ÷ Power consumption

A unit's Coefficient of Performance (COP) refers to its energy consumption efficiency. A larger COP means greater energy efficiency, resulting in less electricity used and thus saving energy.


Top-Class Quiet operation

3 dB down

25 dB Indoor Unit Sound Level

A quiet indoor unit is important for your personal comfort and the SUPER MULTI NX offers a quiet sound level of 25 dB, 2 dB lower than conventional models.
Note: Capacity may decrease when Quiet Operation is selected.

* Contact the distributor in your country for details.


Quiet Operation (indoor unit)

Quiet Operation (indoor unit)

The operation sound of the indoor unit can be decreased 2 or 3 dB below the "Low" fan speed setting by simply pushing the fan speed button on the remote controller.


3 dB down

43 dB Outdoor Unit Sound Level

A quiet outdoor unit is essential for peace in your neighborhood and the SUPER MULTI NX offers a quiet sound level of 43 dB.
Note: Capacity may decrease when quiet operation is selected.

* Contact the distributor in your country for details.


(outdoor unit)

Quiet Operation (outdoor unit)

Priority-room setting also allows outdoor unit quiet operation to be selected by one command* from the priority room.

* If Priority-Room Setting has not been set, the Outdoor unit quiet operation button must be pushed on the wireless remote controller of all indoor units operating at that time.

Night Quiet (Initial setting required during installation)

The outdoor unit's operation sound at night is automatically decreased 3 dB below the rated operation. (Available for cooling only.) Night Quiet starts automatically when the outdoor temperature has dropped by 6℃ from the maximum temperature recorded during the daytime.


Levels of quiet

Levels of quiet